4BioDx
5-diagnostics
Advansta
ABCR
ARDL
Ancestral
Abnova
Alfa Aesar
ATCC
ALPCO
Aquatic Diagnostics Ltd
AURION
Amsbio
Abbexa
Alpha Diagnostic International
Alomone Labs
American Diagnostica GmbH
AESKU.GROUP
AnaSpec
Anshlabs
Abbott
Anti-PEG
Assay Biotech
Activity Signaling
Amid Biosciences
AUSTRAL Biologicals
Antibodies Inc
AngioBio
Alzet
ApexBio
Aves Labs
BellBrook Labs
Biocheck
Biomedica Immunoassay
Biomatik
BD
Biomedica Diagnostic
Biotium
Biocytex
Bachem
Bmrsupply
BioAssay Systems
Biolog
BMA Biomedicals
Bovogen
Bone Slice
Brookwood Biomedical
Biopro
BioPorto
Biomerica
碧云天
Biosensis
CompTech
Click chemistry
Cal Bioreagents
Cytoskeleton
Corning
ChromoTek
Citeq Biologics
Crystal Chem
Calbiotech
Cygnus technologies
Chondrex
Cosmo Bio Co., Ltd
Cytodiagnostics
CytoSpring LLC
Cambridge Research Biochemicals
CIL
Cytodiagnostics
Cell-IN
DSMZ
Diaclone
Demeditec
Discovery® Antibodies
Diazyme
Diamyd Medical
Enzymax
Endocrine-tech
Equitech-Bio
Epigentek
Epitope
Euro Diagnostica
Expedeon
EPC
ECM Biosciences
Enzyme Research Laboratories
Echelon Biosciences
ELISAGenie
Endocrinetech
EKF Life Sciences
Electron Microscopy Sciences
Epicypher
Ethos Biosciences
Fina Bio
FD NeuroTechnologies, Inc
Fitzgerald
Fluorochrome
Fujirebio
Gold Biotechnology
Genesis
GroPep
GREER
GlycoTech
Gemibio
Golden West
Gendepot
Genway
GlycoNZ
Gbiosciences
Hello Bio
Hycultbiotech
Hooke labs
Hitobiotec
Hypoxyprobe
HMGBiotech
HLA Protein
Immuno Star
Immunodiagnostik
Innoprot
IDS
Immunolab GmbH
Immudex
Innovative Research
Innovative Research of America
ImmuSmol
ImmunoGuide
Idylle
Intrinsic LifeSciences
Immuno Chemistry
Jackson Immuno Research
JPT Peptide Technologies GmbH
Kova
Kamiya
Kerafast
Kainos Laboratories
Katchem
Kinexus Bioinformatics
LC Laboratories
LDN
Life Diagnostics
Lab Bioreagents
Linshin Canada
Levena biopharma
Lee BioSolutions
Lumafluor
Louisville APL
Mabtech
Medgene Labs
Millipore
MyBioSource
Molecular Innovations
MatTek
MRC PPU
MD Biosciences
Marvelgent
Medkoo
Matrixome
Metabiologics
Micropoint Technologies
Matrigen
Molecular Depot
Molecular Devices
Novatec
Novocib
NanoLight
NeuroMab
Nanosoft Polymers
NanoTag
NBS-C BioScience
Novabioassays
Oxford Biomedica
Omicron Biochemicals, Inc.
Probetex
Peninsula Laboratories
Progen
Phoenix Pharmaceuticals
Peptides International
ProSpec
PeproTech
phosphosolutions
Prolume Ltd
Proimmune
ProtiFi
Profoldin
ProAxsis
PNA Bio
Quidel
QuickZyme
Quanta BioSciences
R&D Systems
RD-Biotech
Syd Labs
SurModics
SOLVO Biotechnology
Sigma-Aldrich
Signosis
SignalChem
SCICONS
Santa Cruz
Southern Biotech
Swant Inc
Sichem
South Bay Bio
Steraloids
Scripps
SM Biochemicals LLC
Scarabgenomics
Sovicell
SAKURA
Signalway Antibody LLC(SAB)
Svar
Spherotech
Smicna
Seven Hills Bioreagents
STEMCELL
Sino Biological
System bio
Specs
solarbio
Targeting Systems
Trevigen
Thermo Fisher
Terrace Biotech
Ted Pella,Inc
TdB Labs
Vector Labs
Viagen
Vielight
Vacara
Wako
XenoTech
Xenometrix
zeptometrix
Zedira
服务热线 400-650-8846
ELISA盒子检测试剂盒
您的位置:首页 > 产品中心 > 免疫学 > 科研检测 > ELISA盒子
Red Fluorescent SR-FLICA® Caspase-8 (LETD) Assay Kit

Red Fluorescent SR-FLICA® Caspase-8 (LETD) Assay Kit

Red Fluorescent SR-FLICA® Caspase-8 (LETD) Assay Kit

联系购买
中文名称:
Red Fluorescent SR-FLICA® Caspase-8 (LETD) Assay Kit
英文名称:
Red Fluorescent SR-FLICA® Caspase-8 (LETD) Assay Kit
品牌:
Immuno Chemistry
货号:
9150
规格:
100 Tests
保存建议:
2-8°C
背景资料:
FLICA® is a powerful method to assess cell death by detecting apoptosis in vitro. Our FLICA® probes are non-cytotoxic Fluorescent Labeled Inhibitors of CAspases that covalently bind to active caspase enzymes. FLICA measures the intracellular process of apoptosis instead of a side-effect, such as the turn-over of phosphatidyl serine, and eliminates the incidence of false positives that often plagues methods like Annexin V and TUNEL staining.To use FLICA®, add it directly to the cell culture media, incubate, and wash. FLICA® is cell-permeant and will efficiently diffuse in and out of all cells. If there is an active caspase enzyme inside the cell, it will covalently bind with FLICA® and retain the red fluorescent signal within the cell. Unbound FLICA® will diffuse out of the cell during the wash steps. Apoptotic cells will retain a higher concentration of FLICA® and fluoresce brighter than non-apoptotic cells. There is no interference from pro-caspases or inactive forms of the enzymes. If the treatment is causing cell death via apoptosis, apoptotic cells will have an elevated level of caspase activity relative to non- apoptotic or negative control cells and fluoresce with FLICA®.Apoptosis is an evolutionarily conserved process of programmed cell suicide. It is centered on a cascade of proteolytic enzymes called caspases that are triggered in response to pro-apoptotic signals. Once activated, caspases cleave protein substrates leading to the eventual disassembly of the cell. Caspases have been identified in organisms ranging from C. elegans to humans. Mammalian caspases play distinct roles in both apoptosis and inflammation. In apoptosis, effector caspases (-3, -6, and -7) are responsible for proteolytic cleavages that lead to cell disassembly. Initiator caspases (-8, -9, and -10) regulate apoptosis upstream. Caspase-1 is associated with inflammasome activity and takes on the role of a key housekeeping enzyme in its conversion of pro-IL-1ß protein into the active IL-1ß cytokine. (Use FLICA® kits #98, #9122, and #9145 to detect caspase-1). Please note that macrophages and monocytes have been shown to rapidly secrete caspase-1 upon activation.Like the majority of other proteases, caspases are synthesized as pro-form precursors that undergo proteolytic maturation, either autocatalytically or in a cascade by enzymes with similar specificity. Active caspase enzymes consist of two large (~20 kD) and two small (~10 kD) subunits that non-covalently associate to form a two heterodimer, tetrameric active caspase.Activated caspase enzymes cleave proteins by recognizing a 3 or 4 amino acid sequence that must include an aspartic acid (D) residue in the P1 position. This C–terminal residue is the target for the cleavage reaction at the carbonyl end. Each FLICA® probe contains a 3 or 4 amino acid sequence that is targeted by different activated caspases. This target sequence is sandwiched between a red fluorescent label, sulforhodamine B (SR), and a fluoromethyl ketone (FMK). A caspase enzyme cannot cleave the FLICA® inhibitor probe; instead, it forms an irreversible covalent bond with the FMK on the target sequence and becomes inhibited from further enzymatic activity.We offer four red SR-FLICA® inhibitors: SR-VAD-FMK, a poly-caspase probe, which may be used as a general reagent to detect apoptosis as it is recognized by all different types of activated caspases; SR- DEVD-FMK, which is preferred by active caspase-3/7; SR-LETD-FMK, which is preferred by active caspase-8; and SR-LEHD-FMK, which is preferred by active caspase-9. We also offer FLICA® inhibitor reagents with a green or far-red label (see our website for more details). Caspases, like most other crucial cell survival enzymes, are somewhat permissive in the target amino acid sequence they will recognize and cleave. Although FLICA® reagents contain the different amino acid target sequences preferred by each caspase, they can also recognize other active caspases when they are present. We encourage validation of caspase activity by an orthogonal technique.FLICA® can be used to label suspension or adherent cells and thin tissue sections. After labeling with SR-FLICA®, cells can be fixed or frozen. For tissues that will be paraffin-embedded after labeling, use our red sulforhodamine SR-FLICA® probes; do not use the green FAM-FLICA® probes as the green FAM dye will be quenched during the paraffin embedding process.Cells labeled with SR-FLICA® can be counter-stained with reagents such as the live/dead stain 7-AAD (catalog # 6163) to distinguish apoptosis from necrosis. Nuclear morphology can be concurrently observed using Hoechst 33342, a blue DNA binding dye (included in FLICA® kits). Cells can be viewed directly through a fluorescence microscope or the fluorescence intensity can be quantified using a fluorescence plate reader or flow cytometer. For best results with flow cytometry, use a yellow or green laser. SR-FLICA® excites at 550-580 nm and emits at 590-600 nm.
货期:
4-6周
样本类型:
Cell culture
检测方法:
Flow cytometry, Fluorescence microscope, fluorescence plate reader
免责声明:
*本产品仅供科研实验使用,不得用于临床诊断。*
说明书:
This in vitro assay employs the red fluorescent inhibitor probe SR-LETD-FMK to label active caspase-8 enzymes in living cells. Analyze samples using fluorescence microscopy, a fluorescence plate reader, or flow cytometry.

快速响应

即时响应 客户需求

正品保障

正品行货 值得信赖

急速物流

发货迅速 快速物流

退还承诺

退换保障 品质无忧

正规发票

发票保障 售后无忧

在线客服X
QQ交谈
微信在线咨询
-服务热线-

400-650-8846

返回顶部